Validity and reliability of Polar® RS800CX heart rate monitor, measuring heart rate in dogs during standing position and at trot on a treadmil
Uppsala Universitet.
Mid Sweden University, Faculty of Human Sciences, Department of Health Sciences.
Uppsala Universitet.
2013 (English)In: Physiology and Behavior, ISSN 0031-9384, E-ISSN 1873-507X, Vol. 114-115, p. 1-5Article in journal (Refereed) Published
Abstract [en]

Abstract

The aim of the present study was to assess criterion validity, and relative and absolute reliability of Polar® RS800CX heart rate monitor, compared to simultaneously recorded electrocardiogram (ECG) data, in measuring heart rate of dogs during standing position and at trot on a treadmill.

Methods

Heart beats from Polar® RS800CX and Cardiostore ECG were recorded simultaneously during seven continuous minutes in standing position and at trot, in 10 adult healthy dogs. Polar® data was statistically compared to ECG data for a variety of mean beats per minute (BPM), standard deviation and confidence interval. Criterion validity was calculated by Pearson product moment correlation method and intraclass correlation coefficient (ICC2.1). Relative and absolute reliability were calculated by ICC2.1, the Bland and Altman analysis and standard error of measurement (SEM and SEM%).

Results

The correlation, criterion validity, between Polar® and ECG data in standing position was r = 0.99 (p < 0.0005) and at trot r = 0.97 (p < 0.0005). Polar® data was not significantly different from ECG data. Mean difference between ECG and uncorrected Polar® data was − 0.6 BPM in standing position and − 0.6 BPM at trot. Polar® was over- and underestimating ECG data. SEM and SEM% in standing were ± 2.6 BPM and 3.0%, at trot ± 3.8 BPM and 3.1%, indicating that measurement errors were low.

Conclusion

This study showed that the criterion validity and the instrument reliability were excellent in Polar® RS800CX heart rate measuring system. The equipment seemed to be valid and reliable in measuring BPM in the dogs studied during submaximal cardiovascular conditions such as in standing position and at trot on a treadmill.

Place, publisher, year, edition, pages
Elsevier, 2013. Vol. 114-115, p. 1-5
National Category
Veterinary Science
Identifiers
URN: urn:nbn:se:miun:diva-22282DOI: 10.1016/j.physbeh.2013.03.002OAI: oai:DiVA.org:miun-22282DiVA, id: diva2:729135
Available from: 2014-06-25 Created: 2014-06-25 Last updated: 2017-12-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Sjöström, Rita

Search in DiVA

By author/editor
Sjöström, Rita
By organisation
Department of Health Sciences
In the same journal
Physiology and Behavior
Veterinary Science

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 158 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf