Mid Sweden University

miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Electron Beam Melting: Moving from Macro- to Micro- and Nanoscale
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för teknik och hållbar utveckling. (SportsTech)
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för teknik och hållbar utveckling. (SportsTech)ORCID-id: 0000-0001-5954-5898
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för teknik och hållbar utveckling.
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för teknik och hållbar utveckling. (SportsTech)
2012 (engelsk)Inngår i: Materials Science Forum, Switzerland: Trans Tech Publications Inc., 2012, Vol. 706-709, s. 532-537Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

This paper presents some results achieved in the biomedical applications of the EBM® technology, and describes the resolved and unresolved challenges presented by modern medical implant manufacturing. In particular it outlines the issues related to the cellular structure design and metal surface modification. Moving to precision control of the metal surface at a microand sub-micrometer scale is a serious challenge to the EBM® processing, because it uses the powder with average grain size of about 0.04 to 0.1 mm. Though manufacturing of components with solidmesh geometry and porous surfaces using EBM® is quite possible, post- processing (for example chemical or electrochemical) is needed to achieve desired control of the surface at smaller scales to realize full potential of the technology for biomedical applications.

sted, utgiver, år, opplag, sider
Switzerland: Trans Tech Publications Inc., 2012. Vol. 706-709, s. 532-537
Serie
Materials Science Forum, ISSN 0255-5476
Emneord [en]
additive manufacturing, electron beam melting, medical implants, surface treatment
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-15586DOI: 10.4028/www.scientific.net/MSF.706-709.532ISI: 000308517300085Scopus ID: 2-s2.0-84856141920OAI: oai:DiVA.org:miun-15586DiVA, id: diva2:468428
Konferanse
7th International Conference on Processing and Manufacturing of Advanced Materials, THERMEC'2011;Quebec City, QC;1 August 2011 through 5 August 2011;Code88200
Tilgjengelig fra: 2011-12-20 Laget: 2011-12-20 Sist oppdatert: 2017-05-03bibliografisk kontrollert
Inngår i avhandling
1. SURFACE PROPERTIES OF IMPLANTS MANUFACTURED USING ELECTRON BEAM MELTING
Åpne denne publikasjonen i ny fane eller vindu >>SURFACE PROPERTIES OF IMPLANTS MANUFACTURED USING ELECTRON BEAM MELTING
2016 (engelsk)Licentiatavhandling, med artikler (Annet vitenskapelig)
Abstract [en]

This thesis summarizes the results concerning the manufacture of medical implants for bone replacement using electron beam melting (EBM) which is an additive manufacturing (AM) technology, and aims to satisfy the engineering needs for the medical functionality of manufacturing technology. This thesis has focused on some microscopic properties for surfaces and bone integration. The process parameters of EBM manufacturing were studied to ascertain whether they have impacts on surface appearance, as surface properties have impacts on bone integration and implant performance.

EBM manufacturing uses an electron beam to melt metal powder onto each layer in a manner akin to welding. The electron beam is controlled by process parameters that may be altered to a certain extent by the operator. There are individual process parameters for every material, and new parameters are set when developing new materials. In this thesis, process parameters in default settings were altered to ascertain whether it was possible to specify process parameters for implant manufacturing. The blood chamber model was used for thromboinflammation validation, using human whole blood. The model is used to identify early reactions of coagulation and immunoreactions. The material used in this study was Ti6Al4V-ELI, which is corrosion resistant and has the same surface oxide layers as titanium, and CoCr-F75, which has high stiffness, is wear-resistant and is commonly used in articulating joints.

The study shows that among the process parameters researched, a combination of speed and current have the most impact on surface roughness and an interaction of parameters were found using design of experiment (DOE). As-built EBM surfaces show thrombogenicity, which in previous studies has been associated with bone ingrowth.

Surface structure of as-build EBM manufactured surfaces are similar to implants surfaces described by Pilliar (2005), but with superior material properties than those of implants with sintered metals beads. By altering the process parameters controlling the electron beam, surface roughness of as-build parts may be affected, and the rougher EBM manufactured surfaces tend to be more thrombogen than the finer EBM manufactured surfaces. As-build EBM manufactured surfaces in general show more thrombogenicity than conventional machined implants surfaces.

Abstract [sv]

Denna avhandling behandlar tillverkning av medicinska implantat för integration i ben. I fokus är den additiva tillverkningstekniken ”elektronstrålesmältning” ( Electron Beam Melting –EBM), en av flera tekniker som populärt beskrivs med termen 3D-skrivare. Avhandlingen fokuserar på mikroskopiska ytegenskaper och dess inverkan på benintegration. Processparametrarna för EBM-tillverkning studerades för att fastställa hur de påverkar ytans utseende, efter som ytegenskaper har effekt på implantatens funktion.

EBM-tillverkning använder en elektronstråle som likt svetsning smälter ihop metallpulver. Elektronstrålen styrs av processparametrar som till viss mån kan justeras av maskinoperatören. Det finns individuella processparametrar för varje material och nya parametrar utvecklas till varje ny legering. I denna avhandling har ”grundinställningarnas processparametrar” studerats för att ta reda på om det är möjligt att ställa in specifika parametrar till implantattillverkning. Med hjälp av blodkammarmetoden, som använder humant blod, har thromboinflammatoriska egenskaper undersökts. Metoden identifierar tidiga koagulations- och immunologiska reaktioner. Legeringarna som undersökts i denna studie var Ti6Al4V-ELI, som är korrosionsbeständigt med samma uppsättning oxider på ytan som titan har, och CoCr-F75, en legering som har hög styvhet, är slitstarkt och är vanligt förekommande i implantat för leder.

Bland de undersökta processparametrarna visar en kombination av hastighet och ström ha mest inverkan på ytjämnhet och en interaktion mellan parametrar identifierades med hjälp av försöksplanering. EBM-tillverkade ytor visade på thrombogena egenskaper som i tidigare studier kan relateras till god integration i benvävnad.

Ytstrukturen hos EBM-tillverkade ytor liknar de implantatytor som Pilliar (2005) beskriver, men materialegenskaperna är bättre än de materialegenskaper som implantat, med sintrad yta, har. Genom att ändra processparametrarna som styr elektronstrålen kan ytstrukturen påverkas. Grövre EBM-tillverkade ytor tenderar att vara mer thrombogena än de finare EBM-tillverkade ytorna är. Obehandlade EBM-tillverkade ytor i allmänhet är mer thrombogena än vad konventionellt framställda implantatytor är.

sted, utgiver, år, opplag, sider
Sweden: Mid Sweden University, 2016. s. 40
Serie
Mid Sweden University licentiate thesis, ISSN 1652-8948 ; 122
Emneord
electron beam melting, blood coagulation, bone ingrowth, surface roughness, process parameters
HSV kategori
Identifikatorer
urn:nbn:se:miun:diva-27125 (URN)978-91-88025-49-4 (ISBN)
Presentation
2016-01-22, G1353, Kunskapens väg 8, Östersund, 13:16 (svensk)
Opponent
Veileder
Tilgjengelig fra: 2016-03-01 Laget: 2016-02-24 Sist oppdatert: 2016-03-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Koptyug, AndreyRännar, Lars-ErikBackstrom, MikaelKlingvall, Rebecca

Søk i DiVA

Av forfatter/redaktør
Koptyug, AndreyRännar, Lars-ErikBackstrom, MikaelKlingvall, Rebecca
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 1947 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf