In Vivo Detection of a pH-Sensitive Nitroxide in the Rat Stomach by Low-Field ESR-Based Techniques
Department of Biomedical Physics and Bioengineering, University of Aberdeen, Aberdeen, UK.
Show others and affiliations
2003 (English)In: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 49, no 3, p. 558-567Article in journal (Refereed) Published
Abstract [en]

A study was made of the in vivo detectability of a pH-sensitive, imidazolidine spin probe, and the efficacy of low-frequency electron spin resonance (ESR)-based techniques for pH measurement in vitro and in vivo in rats. The techniques used were longitudinally-detected ESR (LODESR) and field-cycled dynamic nuclear polarization (FC-DNP) for in vitro and in vivo measurements, and radiofrequency (RF)- and X-band ESR for comparisons in vitro. The spin probe was hexamethyl imidazolidine (HMI) with a pK of 4.6. All techniques detected HMI. Detection by FC-DNP implies coupling between the free radical and solvent water spins. Separations between the three spectral lines of the nitroxide radical, relative to measurement frequency, were consistent with theory. The overall spectrum width from unprotonated HMI (pH > pK) was greater than that from protonated agent (pH < pK). This was observed in vitro and in vivo. Longer-term studies showed that HMI is detectable and has the same spectral width (i.e., is at the same pH) up to 2 hr after gavage into the stomach, although the magnitude of the signal decreases rapidly during the first hour. These findings demonstrate the suitability of LODESR and FC-DNP for monitoring HMI and measuring pH in vivo. These techniques would be useful for monitoring disease and drug pharmacology in the living system.

Place, publisher, year, edition, pages
Wiley InterScience , 2003. Vol. 49, no 3, p. 558-567
Keywords [en]
in vivo; in-vitro; experimental; measurements; rat; ESR; spin probe; free radical
National Category
Physiology Atom and Molecular Physics and Optics
Identifiers
URN: urn:nbn:se:miun:diva-10092DOI: 10.1002/mrm.10392OAI: oai:DiVA.org:miun-10092DiVA, id: diva2:273034
Available from: 2009-10-19 Created: 2009-10-19 Last updated: 2018-01-12Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Koptioug, Andrei

Search in DiVA

By author/editor
Koptioug, Andrei
In the same journal
Magnetic Resonance in Medicine
PhysiologyAtom and Molecular Physics and Optics

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 845 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf