In situ measurements of thermal properties of building fabrics using thermography under non-steady state heat flow conditions
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Avdelningen för ekoteknik och hållbart byggande. (The Ekoteknik research group)ORCID-id: 0000-0001-5356-7471
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Avdelningen för ekoteknik och hållbart byggande.
2018 (engelsk)Inngår i: Infrastructures, ISSN 2412-3811, Vol. 3, nr 3, artikkel-id 20Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This study describes a quantitative method using thermography to measure the thermal properties of building fabrics that are subjected to non-steady state heat flow due to consistently changing meteorological conditions. The method includes two parts. First, the convection heat transfer coefficient is measured by thermography and heat flux meters on a small segment of the examined building fabric with uniform surface temperature. Then, thermal properties of large building fabrics are evaluated by thermography. The two parts are measured simultaneously. The method was tested on 140/160/190 mm thick massive laminated spruce timber walls of a test facility cabin located in Östersund, Sweden. The results varied by only a few percent in comparison to validation measurements performed with heat flux meters and in comparison, to values from the literature. Due to rapid changes in weather conditions the measured values had large disparity, but still a linear regression with low confidence interval was obtained. Obtaining an accurate value of convection heat transfer was important for achieving high measurement accuracy and, therefore, the value of this parameter should be measured. Other important factors to consider are solar radiation, reflected infrared (IR) radiation from nearby objects and the number of thermal images.

sted, utgiver, år, opplag, sider
MDPI, 2018. Vol. 3, nr 3, artikkel-id 20
Emneord [en]
Conductivity, building fabrics, thermal transmittance, thermal imaging, thermography, U-value, heat flux meters
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-34869DOI: 10.3390/infrastructures3030020OAI: oai:DiVA.org:miun-34869DiVA, id: diva2:1261959
Tilgjengelig fra: 2018-11-09 Laget: 2018-11-09 Sist oppdatert: 2018-11-14bibliografisk kontrollert

Open Access i DiVA

fulltext(5714 kB)110 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 5714 kBChecksum SHA-512
564319e34c758e8a8f2e130d27a39c26b581ffc6e0e1630f55fb76cb3a10d3a51ebe9b6f1d3c943f091f527239da45931afb6dc2dd87659ba70b0d30fc1ce1ec
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekst

Personposter BETA

Danielski, ItaiFröling, Morgan

Søk i DiVA

Av forfatter/redaktør
Danielski, ItaiFröling, Morgan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 110 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 152 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf