Fuktstudie av en klimatvind på ett äldre småhus: En utredning av effekterna på vindsklimatet vid utvändig takisolering
Mid Sweden University, Faculty of Science, Technology and Media, Department of Ecotechnology and Sustainable Building Engineering.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Mögelpåväxt orsakat av fuktproblem är vanligt förekommande på kallvindar i det svenska småhusbeståndet. Enligt en rapport från Boverket har var femte småhus en fuktskada på vinden orsakad av hög relativ fuktighet. Statistik från samma rapport visar att äldre hus med självdragsventilation är drabbade i större utsträckning. Luftläckage av fuktig inomhusluft till vind uppges vara en orsak bakom förhöjd luftfuktighet. Äldre hus är oftast inte lika lufttäta som moderna vilket gör dessa kallvindar mer utsatta. Att tilläggsisolera yttertaket utifrån har visat sig vara en åtgärd som sänker den relativa fuktigheten på kallvindar. Detta brukar kallas för att bygga om kallvinden till en klimatvind.

 

Denna studie baserar sig på en klimatvind på ett äldre småhus beläget i Skellefteå kommun. Den tidigare kallvinden var drabbad av fuktskador och byggdes därför om till en klimatvind 2014. Sedan dess har ingen utvärdering gjorts om detta är tillräckligt för att fuktsäkra vinden. Syftet med denna studie är därför att ta reda på om klimatvinden på detta hus är fuktsäker till följd av ombyggnaden. Resultatet kommer att användas som ett underlag för att besluta om fler åtgärder är nödvändiga för att fuktsäkra vinden.

 

För att bedöma fuktsäkerheten har mätningar av temperatur och relativ fuktighet på klimatvinden utförts. Under samma period utfördes även likadana mätningar på en traditionellt uppbyggd kallvind belägen 150 meter från klimatvinden. Genom att jämföra mätresultat mellan dessa vindar kan slutsatser om den utvändiga isoleringens effekt på vindsklimatet göras.

 

Resultatet av klimatmätningarna visar att den relativa fuktigheten på klimatvinden har legat långt under kritisk nivå för mögeltillväxt. Under samma mätperiod har relativ fuktighet på referensvinden varit i närheten av kritiska nivåer. Klimatvinden har i jämförelse med referensvinden ett varmare och torrare klimat och påverkas inte i lika stor utsträckning av svängningarna i utomhusklimatet. Slutsatsen är att klimatvinden anses vara fuktsäker under mätperioden. Rekommendationen är att fortsätta med klimatmätningar under en helårsperiod för att kunna bedöma fuktsäkerheten ur ett helårsperspektiv.

Abstract [en]

Mold growth caused by moisture are common in cold attics in small houses in Sweden. According to a report from the National Board of Housing - Boverket, a fifth of all attics in small houses in sweden has moisture problems caused by increased levels of relative humidity. Statistics from the same report show that older houses with natural draft ventilation are affected to a greater extent. Air leakage of damp indoor air into the attic space is said to be one cause of increased humidity. The construction of older houses are usually not as airtight compared to modern houses. This makes the attics in old houses more vulnerable to this problem. Additionally insulation with eps insulation at the outside of the roof has been shown to reduce the relative humidity in cold attics. This report refers to attics with this type of construction as a ”climate attic”

 

This study is based on a climate attic of a older house located in Skellefteå municipality. The former cold attic had mold problems caused by moisture and was therefore converted to a climate attic in 2014. Since then, no evaluation has been made of the moisture saftey in this climate attic. The purpose of this study is therefore to find out if the climate attic in this house is moisture safe due to the conversion. The results will be used to determining whether more actions are necessary to make the attic moisture safe.

 

In order to evaluate the moisture safety in the climate attic, measurements of temperature and relative humidity has been made. During the same period measurements were made in a traditionally cold attic. By comparing measurement results between those attics conclusions of the effect from the external isolation can be made.

The results from the measurements made in the climate attic shows that the relative humidity has been far below critical levels for mold growth. During the same period the relative humidity in the traditional cold attic has been close to critical levels. In comparison with the traditionally cold attic, the climate attic has a warmer and drier climate and is not affected to the same extent by the fluctuations in the outdoor climate. The conclusion is that the climate attic are considered to be moistureproof during the time measurement was made. The recommendation is to continue with climate measurements over a full-year period to assess moisture safety from a full-year perspective.

Place, publisher, year, edition, pages
2017. , p. 51
Keywords [en]
Cold attic, roof insulation, moisture, mold, additional insulation
Keywords [sv]
Klimatvind, kallvind, takisolering, tilläggsisolering, fukt, mögel, fuktkvot, fukthalt, Relativ fuktighet, diffusion, konvektion, ventilation
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:miun:diva-32839DOI: BT-V17-G3-014OAI: oai:DiVA.org:miun-32839DiVA, id: diva2:1182364
Subject / course
Building Engineering BY1
Educational program
Building Engineering Sustainable Building TBYHG 180 higher education credits
Supervisors
Examiners
Note

Kull H14

Available from: 2018-08-30 Created: 2018-02-13 Last updated: 2018-08-30Bibliographically approved

Open Access in DiVA

fulltext(4300 kB)38 downloads
File information
File name FULLTEXT01.pdfFile size 4300 kBChecksum SHA-512
4d72fae9bb0db57a51c52e5bce21a4f7f383224e5a4963e78d6cb19cfed8fd715ad308dd1741c514ac6170d8538a6e102985df4be6627710875de364324e1f14
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Laiti, Pär-Henrik
By organisation
Department of Ecotechnology and Sustainable Building Engineering
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 38 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 253 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf