miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Breathing resistance in automated metabolic systems is high in comparison with the Douglas Bag method and previous recommendations
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Avdelningen för kvalitets- och maskinteknik. (Sportstech)
Syddansk Universitet, Odense, Danmark.
Swedish School of Sport and Health Sciences, GIH, Stockholm.
2018 (engelsk)Inngår i: Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology, ISSN 1754-3371, Vol. 232, nr 2, s. 122-130Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The purpose of this study was to investigate the resistance (RES) to breathing in metabolic systems used for the distribution and measurement of pulmonary gas exchange. A mechanical lung simulator was used to standardize selected air flow rates ( , L/s). The delta pressure (∆p, Pa) between ambient air and the air inside the equipment was measured in the breathing valve’s mouthpiece adapter for four metabolic systems and four types of breathing valves. RES for the inspiratory and expiratory sides was calculated as RES = ∆p / , Pa/L/s. The results for RES showed significant (p < 0.05) between-group variance among the tested metabolic systems, as well as the breathing valves and between most of the completed . The lowest RES among the metabolic systems was found for a Douglas Bag system, with approximately half of the RES compared to the automated metabolic systems. The automated systems were found to have higher RES already at low  in comparison to previous recommendations. For the hardware components, the highest RES was found for the breathing valves while the lowest RES was found for the hoses. Conclusion: The results showed that RES in metabolic systems can be minimized through conscious choices of system design and hardware components. 

sted, utgiver, år, opplag, sider
2018. Vol. 232, nr 2, s. 122-130
Emneord [en]
Breathing valve, delta pressure, flow meter, hose, mixing chamber, oxygen uptake
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-29508DOI: 10.1177/1754337117715946ISI: 000432622900006Scopus ID: 2-s2.0-85047149312OAI: oai:DiVA.org:miun-29508DiVA, id: diva2:1055218
Tilgjengelig fra: 2016-12-12 Laget: 2016-12-12 Sist oppdatert: 2018-11-05bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Ainegren, Mats

Søk i DiVA

Av forfatter/redaktør
Ainegren, Mats
Av organisasjonen
I samme tidsskrift
Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 786 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf