Effect of test conditions on measured loads and displacements in zero and short span testing
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för teknik, fysik och matematik.
2003 (Engelska)Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Single fibre mechanical properties play a critical role in determining sheet mechanical properties, but these mechanical properties are rarely measured due to the time-consuming nature of the tests. The zero span strength is commonly used as a measure for the strength of the fibres, but the results also can depend on the test conditions. Modelling has shown that the load displacement curves are influenced by the thickness to span ratio, as there is an in-homogenous stress-field in the thickness direction of the sample. This paper will present data on the effect of grammage and clamping pressure on the loads and displacements in zero/short span tests. Clamps were designed and made for a displacement controlled load frame made by Material Testing System (MTS). These clamps can test up to ten plies of papers with a span length from 0 to 3 mm. For the sake of comparison, tests were made using a commercial zero/short span tester, which is load controlled but is limited in span length and thickness of the tested material. Both machines were found to give comparable results. Isotropic 65 gsm handsheets, 36 gsm aluminium foil and 42 gsm greaseproof paper (MD and CD) were tested as functions of clamping pressure and grammage. An intrinsic zero-span strength was defined as the y-axis intercept of plot. A recently published procedure for determining the short span stress-strain curve from zero and short span testing was evaluated for the effect of grammage, clamping pressure and span on the calculated result. It was concluded that the method only gives results that are independent of the test conditions when the conditions are carefully selected.

Ort, förlag, år, upplaga, sidor
2003. s. 115-120
Identifikatorer
URN: urn:nbn:se:miun:diva-29040Scopus ID: 2-s2.0-0242409697OAI: oai:DiVA.org:miun-29040DiVA, id: diva2:1033021
Konferens
International Paper Physics Conference, Proceedings
Anmärkning

Conference Paper

Tillgänglig från: 2016-10-05 Skapad: 2016-10-05 Senast uppdaterad: 2016-10-10Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Scopus

Personposter BETA

Gradin, Per A.

Sök vidare i DiVA

Av författaren/redaktören
Gradin, Per A.
Av organisationen
Institutionen för teknik, fysik och matematik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 765 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf