Validity and reliability of Polar® RS800CX heart rate monitor, measuring heart rate in dogs during standing position and at trot on a treadmil
Uppsala Universitet.
Mittuniversitetet, Fakulteten för humanvetenskap, Avdelningen för hälsovetenskap.
Uppsala Universitet.
2013 (Engelska)Ingår i: Physiology and Behavior, ISSN 0031-9384, E-ISSN 1873-507X, Vol. 114-115, s. 1-5Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Abstract

The aim of the present study was to assess criterion validity, and relative and absolute reliability of Polar® RS800CX heart rate monitor, compared to simultaneously recorded electrocardiogram (ECG) data, in measuring heart rate of dogs during standing position and at trot on a treadmill.

Methods

Heart beats from Polar® RS800CX and Cardiostore ECG were recorded simultaneously during seven continuous minutes in standing position and at trot, in 10 adult healthy dogs. Polar® data was statistically compared to ECG data for a variety of mean beats per minute (BPM), standard deviation and confidence interval. Criterion validity was calculated by Pearson product moment correlation method and intraclass correlation coefficient (ICC2.1). Relative and absolute reliability were calculated by ICC2.1, the Bland and Altman analysis and standard error of measurement (SEM and SEM%).

Results

The correlation, criterion validity, between Polar® and ECG data in standing position was r = 0.99 (p < 0.0005) and at trot r = 0.97 (p < 0.0005). Polar® data was not significantly different from ECG data. Mean difference between ECG and uncorrected Polar® data was − 0.6 BPM in standing position and − 0.6 BPM at trot. Polar® was over- and underestimating ECG data. SEM and SEM% in standing were ± 2.6 BPM and 3.0%, at trot ± 3.8 BPM and 3.1%, indicating that measurement errors were low.

Conclusion

This study showed that the criterion validity and the instrument reliability were excellent in Polar® RS800CX heart rate measuring system. The equipment seemed to be valid and reliable in measuring BPM in the dogs studied during submaximal cardiovascular conditions such as in standing position and at trot on a treadmill.

Ort, förlag, år, upplaga, sidor
Elsevier, 2013. Vol. 114-115, s. 1-5
Nationell ämneskategori
Veterinärmedicin
Identifikatorer
URN: urn:nbn:se:miun:diva-22282DOI: 10.1016/j.physbeh.2013.03.002OAI: oai:DiVA.org:miun-22282DiVA, id: diva2:729135
Tillgänglig från: 2014-06-25 Skapad: 2014-06-25 Senast uppdaterad: 2017-12-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Sjöström, Rita

Sök vidare i DiVA

Av författaren/redaktören
Sjöström, Rita
Av organisationen
Avdelningen för hälsovetenskap
I samma tidskrift
Physiology and Behavior
Veterinärmedicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 158 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf