The Percival 2-Megapixel monolithic active pixel imager
DESY, Hamburg, Germany; CFEL, Hamburg, Germany.
DESY, Hamburg, Germany; CFEL, Hamburg, Germany.
DESY, Hamburg, Germany; CFEL, Hamburg, Germany.
DESY, Hamburg, Germany; CFEL, Hamburg, Germany.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Journal of Instrumentation, ISSN 1748-0221, E-ISSN 1748-0221, Vol. 14, nr 1, artikel-id C01006Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The peak brilliance reached by today's Free-Electron Laser and Synchrotron light sources requires photon detectors matching their output intensity and other characteristics in order to fully realize the sources' potential. The Pixellated Energy Resolving CMOS Imager, Versatile And Large (Percival) is a dedicated soft X-ray imager (0.25-1 keV) developed for this purpose by a collaboration of DESY, Rutherford Appleton Laboratory/STFC, Elettra Sincrotrone Trieste, Diamond Light Source, and Pohang Accelerator Laboratory. Following several generations of prototypes, the Percival "P2M" 2-Megapixel imager - a 4.5x5 cm monolithic, stitched sensor with an uninterrupted imaging area of 4x4 cm(2) (1408x1484 pixels of 27x27 mu m - was produced and has demonstrated basic functionality with a first-light image using visible light. It is currently being brought to full operation in a front-illuminated configuration. The readout system being commissioned in parallel has been developed specifically for this imager which will produce - at full 300 Hz frame rate - data at 20 Gbit/s. A first wafer with eight Percival P2M chips has undergone backthinning to enable soft X-ray detection. It has been diced and chips are currently being wirebonded. We summarize here the P2M system, the project status, and show the P2M sensor's first response to visible light.

Ort, förlag, år, upplaga, sidor
2019. Vol. 14, nr 1, artikel-id C01006
Nyckelord [en]
Instrumentation for FEL, X-ray detectors
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:miun:diva-35658DOI: 10.1088/1748-0221/14/01/C01006ISI: 000454851900006Scopus ID: 2-s2.0-85062534223OAI: oai:DiVA.org:miun-35658DiVA, id: diva2:1289197
Konferens
20th International Workshop on Radiation Imaging Detectors, Sundsvall, SWEDEN, JUN 24-28, 2018
Tillgänglig från: 2019-02-15 Skapad: 2019-02-15 Senast uppdaterad: 2019-03-25Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Graafsma, Heinz

Sök vidare i DiVA

Av författaren/redaktören
Graafsma, Heinz
Av organisationen
Institutionen för elektronikkonstruktion
I samma tidskrift
Journal of Instrumentation
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 95 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf