miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The mu TPC method: improving the position resolution of neutron detectors based on MPGDs
European Spallat Source ESS AB, SE-22100 Lund, Sweden.
European Spallat Source ESS AB, SE-22100 Lund, Sweden.
Linkoping Univ, IFM, SE-58183 Linkoping, Sweden.
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Avdelningen för elektronikkonstruktion.ORCID-id: 0000-0003-3221-2086
Vise andre og tillknytning
2015 (engelsk)Inngår i: Journal of Instrumentation, ISSN 1748-0221, E-ISSN 1748-0221, Vol. 10, P04004Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Due to the He-3 crisis, alternatives to the standard neutron detection techniques are becoming urgent. In addition, the instruments of the European Spallation Source (ESS) require advances in the state of the art of neutron detection. The instruments need detectors with excellent neutron detection efficiency, high rate capabilities and unprecedented spatial resolution. The Macromolecular Crystallography instrument (NMX) requires a position resolution in the order of 200 mu m over a wide angular range of incoming neutrons. Solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are proposed to meet the new requirements. Charged particles rising from the neutron capture have usually ranges larger than several millimetres in gas. This is apparently in contrast with the requirements for the position resolution. In this paper, we present an analysis technique, new in the field of neutron detection, based on the Time Projection Chamber (TPC) concept. Using a standard Single-GEM with the cathode coated with (B4C)-B-10, we extract the neutron interaction point with a resolution of better than sigma = 200 mu m.

sted, utgiver, år, opplag, sider
2015. Vol. 10, P04004
Emneord [en]
Particle tracking detectors, Time projection Chambers (TPC), Micropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc), Neutron detectors (cold, thermal, fast neutrons)
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-25687DOI: 10.1088/1748-0221/10/04/P04004ISI: 000357961700049Lokal ID: STCOAI: oai:DiVA.org:miun-25687DiVA: diva2:849130
Tilgjengelig fra: 2015-08-27 Laget: 2015-08-18 Sist oppdatert: 2016-12-20bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Hall-Wilton, Richard
Av organisasjonen
I samme tidsskrift
Journal of Instrumentation

Søk utenfor DiVA

GoogleGoogle Scholar

Altmetric

Totalt: 113 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf