miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Non-Destructive Method to Resolve the Core and the Coating on Paperboard by Spectroscopic X-ray Imaging
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Avdelningen för elektronikkonstruktion. (Radiation Sensor Systems)
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Avdelningen för elektronikkonstruktion. (Radiation Sensor Systems)
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Avdelningen för elektronikkonstruktion. (Radiation Sensor Systems)
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Avdelningen för elektronikkonstruktion. (Radiation Sensor Systems)ORCID-id: 0000-0002-8325-5177
2013 (engelsk)Inngår i: Nordic Pulp & Paper Research Journal, ISSN 0283-2631, E-ISSN 2000-0669, Vol. 28, nr 3, s. 439-442Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Quality control is an important issue in the paperboard industry. A typical sheet of paperboard contains a core of cellulose fibers [C6H10O5], coated on one or both sides with layers of calcium carbonate [CaCO3] or Kaolin [Al2Si2O5(OH)4]. One of the major properties of a good quality paperboard is the consistency of the expected ratio between the thickness of the core and the coating layers. A measurement system to obtain this ratio could assist the paperboard industry to monitor the quality of their products in an automatic manner. In this work, the thicknesses of the core and the coating layers on a paperboard with coating layer on only one side were measured using an X-ray imaging technique. However, the limited spectral and spatial resolution offered by the measurement system being used led to the measured thicknesses of the layers being lower than their actual thicknesses in the paperboard sample. Suggestions have been made in relation to overcoming these limitations and to enhance the performance of the method. A Monte Carlo N-particle code simulation has been used in order to verify the suggested method.

sted, utgiver, år, opplag, sider
2013. Vol. 28, nr 3, s. 439-442
Emneord [en]
Spectroscopic X-ray imaging, Thickness measurement of layers in paperboard, Paperboard quality
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-18400ISI: 000325145900014Scopus ID: 2-s2.0-84883036103Lokal ID: STCOAI: oai:DiVA.org:miun-18400DiVA, id: diva2:602045
Tilgjengelig fra: 2013-01-31 Laget: 2013-01-31 Sist oppdatert: 2017-12-06bibliografisk kontrollert
Inngår i avhandling
1. Phase-Contrast and Spectroscopic X-ray Imaging for Paperboard Quality Assurance
Åpne denne publikasjonen i ny fane eller vindu >>Phase-Contrast and Spectroscopic X-ray Imaging for Paperboard Quality Assurance
2014 (engelsk)Licentiatavhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The end-use performance of a paperboard depends on its quality.

The major properties of a good quality paperboard include consistency

in the expected ratio between the thickness of the core and

the coating layers, and the uniformity in the coating layer. Measurement

systems using X-rays to monitor these properties could assist

the paperboard industries to assure the quality of their products in a

non-destructive and automatic manner.

 

Phase Contrast X-ray Imaging (PCXI) has been used successfully

to look inside a wide range of objects using synchrotron radiation

sources. Recent advancements in the grating interferometer based

PCXI technique enables high quality phase-contrast and dark-field

images to be obtained using conventional X-ray tubes. The darkfield

images map the scattering inhomogeneities inside objects and

is very sensitive to micro-structures, and thus, can reveal useful information

about the object’s inner structures, such as, the fibre structures

inside paperboards.

 

In this thesis, methods, using spectroscopic X-ray imaging and

PCXI technique have been demonstrated to measure paperboard quality.

The thicknesses of the core and the coating layers on a paperboard

with the coating layer on only one side can be measured using

spectroscopic X-ray imaging technique. However, the limited

spectral and spatial resolution offered by the measurement system

being used led to the measured thicknesses of the layers being lower

than their actual thicknesses in the paperboard sample. Suggestions

have been made in relation to overcoming these limitations and to

enhance the performance of the method.

 

The dark-field signals from paperboard samples with different quality

indices are analysed. The isotropic and the anisotropic scattering

coefficients for all of the samples have been calculated. Based

on the correlation between the isotropic coefficients and the quality

indices of the paperboards, suggestions have been made for paperboard

quality measurements.

sted, utgiver, år, opplag, sider
Sundsvall: Mid Sweden University, 2014. s. 96
Serie
Mid Sweden University licentiate thesis, ISSN 1652-8948 ; 110
HSV kategori
Identifikatorer
urn:nbn:se:miun:diva-21910 (URN)STC (Lokal ID)978-91-87557-46-0 (ISBN)STC (Arkivnummer)STC (OAI)
Presentation
2014-05-22, M102, Sundsvall, 10:15 (engelsk)
Opponent
Veileder
Forskningsfinansiär
Knowledge Foundation
Tilgjengelig fra: 2014-05-12 Laget: 2014-05-06 Sist oppdatert: 2017-03-06bibliografisk kontrollert
2. Advanced X-ray Detectors for Industrial and Environmental Applications
Åpne denne publikasjonen i ny fane eller vindu >>Advanced X-ray Detectors for Industrial and Environmental Applications
2016 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The new generation of X-ray free electron laser sources arecapable of producing light beams with billion times higherpeak brilliance than that of the best conventional X-ray sources.This advancement motivates the scientific community to pushforward the detector technology to its limit, in order to de-sign photon detectors which can cope with the extreme fluxgenerated by the free electron laser sources. Sophisticated ex-periments like deciphering the atomic details of viruses, filmingchemical reactions or investigating the extreme states of matterrequire detectors with high frame rate, good spatial resolution,high dynamic range and large active sensor area. The PERCI-VAL monolithic active pixel sensor is being developed by aninternational group of scientists in collaboration to meet theaforementioned detector requirements within the energy rangeof 250 eV to 1 keV, with a quantum efficiency above 90%.In this doctoral researchwork, Monte Carlo algorithm basedGeant4 and finite element method based Synopsys SentaurusTCADtoolkits have been used to simulate, respectively, theX-rayenergy deposition and the charge sharing in PERCIVAL. Energydeposition per pixel and charge sharing between adjacent pixelsat different energies have been investigated and presented.Novel methods for industrial and environmental applica-tions of some commercially available X-ray detectors have beendemonstrated. Quality inspection of paperboards by resolv-ing the layer thicknesses and by investigating orientation ofthe cellulose fibres have been performed using spectroscopicand phase-contrast X-ray imaging. It was found that, usingphase-contrast imaging it is possible to set burn-out like qualityindex on paperboards non-destructively. X-ray fluoroscopicmeasurements have been conducted in order to detect Cr inwater. This method can be used to detect Cr and other toxicelements in leachate in landfills and other waste dumping sites.

Abstract [sv]

Acceleratorbaserade röntgenkällor utvecklas ständigt, dessakan producera röntgenstrålning med miljarder gånger så högeffekttäthet som de starkaste konventionella röntgenkällorna.Därför finns en vetenskaplig utmaning att utveckla röntgende-tektorer som inte förstörs i de extrema flöden som genereras avdessa röntgenkällor. De visioner som finns för de nya källornaär t.ex.; att avbilda detaljer av virus ner på atomnivå, att filmakemiska reaktioner eller att undersöka extrema tillstånd hos ma-teria. Dessa typer av experiment kräver röntgendetektorer medhög bildhastighet, hög spatial upplösning och stort intensitets-omfång och stor aktiv sensoryta. Detektorsystemet PERCIVALsom bygger på aktiva pixlar med energiupplösning utvecklasinom ett internationellt vetenskapligt samarbetsprojekt. Må-let är att uppfylla detektorspecifikationerna för de nämndaexperimenten inom energiområdet 250 eV till 1 keV, med enkvantverkningsgrad över 90 %.I föreliggande vetenskapliga avhandlingsarbete har simule-ringar av energideponering i PERCIVAL-detektorn genomförtsbaserat på Monte Carlo-algoritmer och simuleringar av ladd-ningsdelning mellan pixlar har simulerats med hjälp av finitaelementmetoden. Därmed har energideponeringen per pixeloch laddningsdelningen mellan närliggande pixlar vid olikaenergier kunnat utredas och presenteras.I avhandlingen demonstreras nya lovande metoder för in-dustriella applikationer och miljöövervakning,därkommersiellttillgängliga röntgendetektorer kan användas. Kvalitetsövervak-ning av kartongtillverkning genom att mäta bestrykningstjock-lek och fiberorientering kan realiseras med energiupplöstaröntgenbilder eller faskontrastbilder i röntgenområdet. Det kankonstateras att med icke-förstörande provning, genom faskon-trastbilder, kan kvalitetsindexvärlden erhållas på samma sättsom kvalitetsindex kan erhållas från ”burn-out”-mätningar.Spektroskopiska mätningar av röntgenflourescens har genom-förts för att detektera krom (Cr) i vatten. Metodik för att detek-tera krom och andra giftiga metaller i lakvatten från deponioch annan lagring för giftigt avfall har utarbetats.

sted, utgiver, år, opplag, sider
Sundsvall: Mid Sweden University, 2016. s. 159
Serie
Mid Sweden University doctoral thesis, ISSN 1652-893X ; 253
HSV kategori
Identifikatorer
urn:nbn:se:miun:diva-29264 (URN)STC (Lokal ID)978-91-88025-84-5 (ISBN)STC (Arkivnummer)STC (OAI)
Disputas
2016-12-01, M108, Sundsvall, 10:15 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2016-11-10 Laget: 2016-11-10 Sist oppdatert: 2017-06-30bibliografisk kontrollert

Open Access i DiVA

Reza_Non-destructive_method(610 kB)946 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 610 kBChecksum SHA-512
20e2f20c33528cba08ab99f97d81e7b971aa24ffe2f826b95cf28210a87738007b0f64ff708f9757dfbc31aa0fe3edaadb5d61bd85592bc5932be84650aeb3c1
Type fulltextMimetype application/pdf

Scopus

Personposter BETA

Reza, SalimNorlin, BörjeThim, JanFröjdh, Christer

Søk i DiVA

Av forfatter/redaktør
Reza, SalimNorlin, BörjeThim, JanFröjdh, Christer
Av organisasjonen
I samme tidsskrift
Nordic Pulp & Paper Research Journal

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 946 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 979 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf