Diving response and arterial oxygen saturation during apnea and exercise in breath-hold divers
Department of Animal Physiology, Lund University.
Lund University Hospital.
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för naturvetenskap.
2002 (engelsk)Inngår i: Journal of applied physiology, ISSN 8750-7587, E-ISSN 1522-1601, Vol. 93, nr 3, s. 882-886Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This study addressed the effects of apnea in air and apnea with face immersion in cold water (10°C) on the diving response and arterial oxygen saturation during dynamic exercise. Eight trained breath-hold divers performed steady-state exercise on a cycle ergometer at 100 W. During exercise, each subject performed 30-s apneas in air and 30-s apneas with face immersion. The heart rate and arterial oxygen saturation decreased and blood pressure increased during the apneas. Compared with apneas in air, apneas with face immersion augmented the heart rate reduction from 21 to 33% (P < 0.001) and the blood pressure increase from 34 to 42% (P < 0.05). The reduction in arterial oxygen saturation from eupneic control was 6.8% during apneas in air and 5.2% during apneas with face immersion (P < 0.05). The results indicate that augmentation of the diving response slows down the depletion of the lung oxygen store, possibly associated with a larger reduction in peripheral venous oxygen stores and increased anaerobiosis. This mechanism delays the fall in alveolar and arterial Po2 and, thereby, the development of hypoxia in vital organs. Accordingly, we conclude that the human diving response has an oxygen-conserving effect during exercise.

sted, utgiver, år, opplag, sider
2002. Vol. 93, nr 3, s. 882-886
Emneord [en]
breath-hold divers, apnea
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-2425DOI: 10.1152/japplphysiol.00863.2001ISI: 000177573400010Scopus ID: 2-s2.0-0036707822Lokal ID: 1614OAI: oai:DiVA.org:miun-2425DiVA, id: diva2:27457
Tilgjengelig fra: 2008-09-30 Laget: 2008-09-30 Sist oppdatert: 2018-01-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Schagatay, Erika

Søk i DiVA

Av forfatter/redaktør
Schagatay, Erika
Av organisasjonen
I samme tidsskrift
Journal of applied physiology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 887 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf